fix for drager voltage when it is an o2 subtype showing incorrectly on the chart

This commit is contained in:
csawatzky 2025-10-28 09:26:46 -06:00
parent 92d4892c65
commit de526ddeb4

View file

@ -170,6 +170,7 @@ export function dragerGasDongle(subtype: number = 0): ComponentTypeExtension {
let firstTime: Moment | undefined; let firstTime: Moment | undefined;
let lastTime: Moment | undefined; let lastTime: Moment | undefined;
let valMap: Map<number, number[]> = new Map<number, number[]>(); let valMap: Map<number, number[]> = new Map<number, number[]>();
if(measurement.type === quack.MeasurementType.MEASUREMENT_TYPE_PPM){
measurement.values.forEach((vals, i) => { measurement.values.forEach((vals, i) => {
let avgVals: Point[] = []; let avgVals: Point[] = [];
let newLineData: LineData = { let newLineData: LineData = {
@ -213,6 +214,15 @@ export function dragerGasDongle(subtype: number = 0): ComponentTypeExtension {
filters filters
); );
} }
} else {
chartData = simpleLineChartData(
quack.ComponentType.COMPONENT_TYPE_DRAGER_GAS_DONGLE,
measurement,
smoothingAverages,
filters
);
console.log(chartData)
}
return chartData; return chartData;
}, },
minMeasurementPeriodMs: 1000 minMeasurementPeriodMs: 1000