fix for the drager voltage showing incorrectly on the chart for o2 subtypes

This commit is contained in:
csawatzky 2025-10-28 09:27:42 -06:00
parent d6f33a873c
commit d63022ca88

View file

@ -170,6 +170,7 @@ export function dragerGasDongle(subtype: number = 0): ComponentTypeExtension {
let firstTime: Moment | undefined; let firstTime: Moment | undefined;
let lastTime: Moment | undefined; let lastTime: Moment | undefined;
let valMap: Map<number, number[]> = new Map<number, number[]>(); let valMap: Map<number, number[]> = new Map<number, number[]>();
if(measurement.type === quack.MeasurementType.MEASUREMENT_TYPE_PPM){
measurement.values.forEach((vals, i) => { measurement.values.forEach((vals, i) => {
let avgVals: Point[] = []; let avgVals: Point[] = [];
let newLineData: LineData = { let newLineData: LineData = {
@ -205,6 +206,14 @@ export function dragerGasDongle(subtype: number = 0): ComponentTypeExtension {
valMap = new Map<number, number[]>(); valMap = new Map<number, number[]>();
} }
}); });
} else {
chartData = simpleLineChartData(
quack.ComponentType.COMPONENT_TYPE_DRAGER_GAS_DONGLE,
measurement,
smoothingAverages,
filters
);
}
} else { } else {
chartData = simpleLineChartData( chartData = simpleLineChartData(
quack.ComponentType.COMPONENT_TYPE_DRAGER_GAS_DONGLE, quack.ComponentType.COMPONENT_TYPE_DRAGER_GAS_DONGLE,